Process Plants Instrumentation

Pressure Regulators: Function & Types

The main function of any gas pressure regulator is to match the flow of gas through the regulator to the demand for gas placed upon the system while maintaining the system pressure within certain acceptable limits. Generally, regulators are simpler devices than control valves. Regulators are self-contained, directed-operated control devices which use energy from the controlled system to operate whereas control valves require external power sources, transmitting instruments and control instruments.

Let’s consider a spring-controlled pressure regulator below:

Spring-controlled pressure regulator
Figure 1.0: Spring-controlled pressure regulator

A spring-controlled regulator is illustrated above. A spring-loaded diaphragm is pushed on by regulated gas pressure. If the regulated gas pressure starts to fall, the reduced pressure on the diaphragm causes it to move downward, thus opening a valve and allowing more high pressure gas in.

Types of Pressure Regulators

Pressure regulators may be classified into the following types:

  • Pressure reducing regulators
  • Backpressure regulators
  • Pressure relief valves
  • Pressure switching valves
  • Vacuum regulators and breakers

Pressure Reducing Regulators

A pressure reducing regulator maintains a desired reduced inlet pressure while providing the required fluid flow to satisfy a downstream demand. The pressure which the regulator maintains is the outlet pressure setting (setpoint) of the regulator. Pressure reducing regulators are further categorised into direct-operated (self-operated) regulators and pilot-operated regulators.

Backpressure Regulators

A backup pressure regulator maintains a desired upstream pressure by varying the flow in response to changes in upstream pressure.

Pressure Relief Valve

A pressure relief valve limits pressure build-up (prevents overpressure) at its location in a pressure system; the relief valve opens to prevent a rise of internal pressure in excess of a specified value. The pressure at which the relief valve starts to open pressure is the relief pressure setting.

In actual fact, pressure relief valves and backpressure regulators are similar devices. The name is usually determined by the application.

Pressure Switching Valves

Pressure switching valves are used in pneumatic logic systems. These valves have either two-way or three-way switching. Two-way switching valves are used for ON/OFF service in pneumatic systems. Three-way switching valves direct inlet pressure from one outlet port to another whenever the sensed pressure exceeds or drops below a preset limit.

Vacuum Regulators and Breakers

Vacuum regulators and breakers are used to control vacuum. A vacuum regulator maintains a constant vacuum at the regulator inlet with a higher vacuum connected at the outlet. During the operation, a vacuum regulator remains closed until a vacuum decrease (a rise in absolute pressure) exceeds the spring setting and opens the valve disk.

A vacuum breaker prevents a vacuum from exceeding a specified value. During operation, a vacuum breaker remains closed until an increase in vacuum (a decrease in absolute pressure) exceeds the spring setting and opens the valve disk.

Don’t miss out on key updates, join our newsletter  List

John Mulindi

John Mulindi is an Industrial Instrumentation and Control Professional with a wide range of experience in electrical and electronics, process measurement, control systems and automation. In free time he spends time reading, taking adventure walks and watching football.

View Comments

Recent Posts

The Problems Associated with Embedded Power Generation

Image source Pixabay The rate of the development of energy sources that are alternatives to…

1 hour ago

The Power of Automation in Construction: How It Transforms Efficiency and Safety

Image by Pixabay Automation is transforming industries worldwide, and construction is no exception. Companies are…

1 day ago

LED Beacon Lights: What Does Each Colour Lens Mean?

A closeup shot of a warning lamp in the street at night, image by Freepik…

2 days ago

Impeller Flowmeters: Features, Installation Considerations & Uses

Impeller flowmeters at times referred to as paddlewheel meters are one of the frequently utilized…

6 days ago

Sell Old Electronics: Turn Your Used Devices into Cash

Photo by Héctor Martínez on Unsplash Introduction Yes! If you have old electronic devices that you…

1 week ago

The Effects of Low Power Factor on Electrical Equipment

The cosine of the angle between voltage and current in an AC circuit is referred…

1 week ago